RCC-02 Remote Control Centre For Studer

Available!

The RCC-02 enables the user to supervise the system and to completely adapt it to the needs through the many parameter settings available on the Xtenders, on the VarioTracks and on the VarioStrings.

You can also download the manual through the link below.
Studer RCC-02 and RCC-03 User Manual

Buy this product through any of the following:

Call to Order

88,700

Available!

Description

The RCC-02 Remote Control Centre For Studer enables the user to supervise the system and to completely adapt it to the needs through the many parameter settings available on the Xtenders, on the VarioTracks and on the VarioStrings.

   1 & 3 Phase System

1 & 3 Phase SystemThanks to its digital display, the RCC-02 provides clear and comprehensive indications on the state of the system in the chosen language.

The device memorizes the events that occurred on an installation and therefore anticipates any future problems.

 

Date Time & Special Function

Date Time & Special Function

A SD card reader is available and allows parameters recording, as well as the uploading of various pre-settings and of all future updates.

Meant for wall mounting.
Dimension H x L x l: 170 x 168 x 43.5 mm.
Supplied with 2 m cable (max. 50m)

You can also download the manual through the link below.
Studer RCC-02 and RCC-03 User Manual

Buy this product through any of the following:

  • Telephone Order – Call 0803 2170 129
  • PRAG Showrooms (Lagos, Port Harcourt or Abuja) Click Here
  • Order from KONGA Click Here
  • Order from JUMIA Click Here

Price Options

xxx

Specifications

Inverter 
Model XTH 6000-48
Nominal battery voltage 48 Vdc
Input voltage range 38 – 68 Vdc
Continuous power @ 25°C 5000 VA
Power 30 min. @ 25°C 6000 VA
Power 5 sec. @ 25°C 15 kVA
Maximum load Up to short-circuit
Asymmetric load Up to Pcont.
Load detection (stand-by) 2 to 25 W
Cos j 0.1-1
Maximum efficiency 96 %
Consumption OFF/Stand-by/ON 1.8 W / 2.2 W / 22 W
Output voltage Pure sine wave 230 Vac (± 2 %) / 120 Vac (1)
Output frequency Adjustable 45 – 60 Hz (1) ± 0.05 % (crystal controlled)
Harmonic distortion < 2 %
Overload and short-circuit protection Automatic disconnection with 3 time restart attempt
Overheat protection Warning before shut-off – with automatic restart
Battery charger
Charge Characteristic 6 steps: Bulk, Absorption, Floating, Equalization, reduced floating, periodic absorption
Number of steps, thresholds, end current and times completely adjustable with the RCC-02/-03
Maximum charging current 100 A
Temperature compensation With BTS-01 or BSP 500/1200
Power Factor Correction (PFC) EN 61000-3-2
General data XTH 6000-48
Input voltage range 150 to 265 Vac / 50 to 140 Vac (1)
Input frequency 45 to 65 Hz
Input current max. (transfer relay) / Output current max. 50 Aac / 56 Aac
Transfer time <15 ms
Multifunction contacts 2 independent contacts (potential free 3 points, 16Aac / 5Adc)
Weight 42 kg
Dimensions h/w/l [mm] 230 / 300 / 500
Protection index IP20
EU declaration of conformity Low Voltage Directive (LVD) 2014/35/EU:
– EN 50178:1997
Electromagnetic Compliance (EMC) Directive 2014/30/EU:
– EN 62040-2:2006, EN 61000-3-2:2014, EN 61000-3-12:2011
Operating temperature range -20 to 55°C
Relative humidity in operation 95 % without condensation
Ventilation Forced from 55°C
Acoustic level < 40 dB / < 45 dB (without/with ventilation)
Warranty 5 years
ISO Certification 9001:2008 / 14001:2004
Accessories
Remote control RCC-02 or RCC-03 Adjustable with the RCC-02/-03
Module Xcom-232i Adjustable with the RCC-02/-03
Communication sets Xcom-LAN / Xcom-GSM / Xcom-SMS Adjustable with the RCC-02/-03
Battery Status Processor BSP Adjustable with the RCC-02/-03
Remote Control Module RCM-10 (3 m) Adjustable with the RCC-02/-03
2 aux. contacts module ARM-02
Cooling Module ECF-01
Battery temp. sensor BTS-01 (3 m) Adjustable with the RCC-02/-03
Communication cable for 3ph and // CAB-RJ45-8-2 Adjustable with the RCC-02/-03
Mounting frame X-Connect
Call Now Button
PRAG INVERTER promo