- True sine wave voltage
- Reliable and silent with any kind of load
- Outstanding overload capabilities
- Smart-Boost function for assistance to the source even with difficult loads
- Automatic reduction of peak loads (power shaving)
- Multi-stage programmable battery charger with PFC (Power Factor Correction)
- Stand-by level adjustable over a large range and from a very low threshold
- Ultra-fast transfer relay
- Control by digital signal processors (DSP)
- High efficiency
- Easy to Install, Operate resolve Solve
3.5kVA/24V Heavy-Duty Inverter- Studer Xtender -(XTM-3500)
₦973,200
Specifications
| Inverter | |
| Model | XTM 3500-24 |
| Nominal battery voltage | 24 Vdc |
| Input voltage range | 19 – 34 Vdc |
| Continuous power @ 25°C | 3000 VA |
| Power 30 min. @ 25°C | 3500 VA |
| Power 5 sec. @ 25°C | 9 kVA |
| Maximum load | Up to short-circuit |
| Asymmetric load | Up to Pcont. |
| Load detection (stand-by) | 2 to 25 W |
| Cos j | 0.1-1 |
| Maximum efficiency | 94 % |
| Consumption OFF/Stand-by/ON | 1.4W / 1.6W /12W |
| Output voltage | Pure sine wave 230 Vac (± 2 %) / 120 Vac (1) |
| Output frequency | Adjustable 45 – 60 Hz (1) ± 0.05 % (crystal controlled) |
| Harmonic distortion | < 2 % |
| Overload and short-circuit protection | Automatic disconnection with 3 time restart attempt |
| Overheat protection | Warning before shut-off – with automatic restart |
| Battery charger | |
| Charge Characteristic | 6 steps: Bulk, Absorption, Floating, Equalization, reduced floating, periodic absorption Number of steps, thresholds, end current and times completely adjustable with the RCC-02/-03 |
| Maximum charging current | 90 A |
| Temperature compensation | With BTS-01 or BSP 500/1200 |
| Power Factor Correction (PFC) | EN 61000-3-2 |
| General data | XTM 3500-24 |
| Input voltage range | 150 to 265 Vac / 50 to 140 Vac (1) |
| Input frequency | 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac |
| Transfer time | <15 ms |
| Multifunction contacts | 2 independent contacts (potential free 3 points, 16Aac / 5Adc) |
| Weight | 21.2 kg |
| Dimensions h/w/l [mm] | 133 / 322 / 466 |
| EU declaration of conformity | Low Voltage Directive (LVD) 2014/35/EU: -EN 50178:1997, EN 62109-1:2010 Electromagnetic Compliance (EMC) Directive 2014/30/EU: – EN 62040-2:2006, EN 61000-3-2:2014, EN 61000-3-12:2011 |
| Operating temperature range | -20 to 55°C |
| Relative humidity in operation | 95 % without condensation |
| Ventilation | Forced from 55°C |
| Acoustic level | < 40 dB / < 45 dB (without/with ventilation) |
| Warranty | |
| ISO Certification | 9001:2008 / 14001:2004 |
| Accessories | |
| Remote control RCC-02 or RCC-03 | Adjustable with the RCC-02/-03 |
| Module Xcom-232i | Adjustable with the RCC-02/-03 |
| Communication sets Xcom-LAN / Xcom-GSM / Xcom-SMS | Adjustable with the RCC-02/-03 |
| Battery Status Processor BSP | Adjustable with the RCC-02/-03 |
| Remote Control Module RCM-10 (3 m) | Adjustable with the RCC-02/-03 |
| 2 aux. contacts module ARM-02 | |
| Cooling Module ECF-01 | |
| Battery temp. sensor BTS-01 (3 m) | Adjustable with the RCC-02/-03 |
| Communication cable for 3ph and // CAB-RJ45-8-2 | Adjustable with the RCC-02/-03 |
| Mounting frame X-Connect | |