RCC-02 Remote Control Centre For Studer

Available!

The RCC-02 enables the user to supervise the system and to completely adapt it to the needs through the many parameter settings available on the Xtenders, on the VarioTracks and on the VarioStrings.

You can also download the manual through the link below.
Studer RCC-02 and RCC-03 User Manual

Buy this product through any of the following:

Call to Order

88,700

Available!

Description

The RCC-02 Remote Control Centre For Studer enables the user to supervise the system and to completely adapt it to the needs through the many parameter settings available on the Xtenders, on the VarioTracks and on the VarioStrings.

   1 & 3 Phase System

1 & 3 Phase SystemThanks to its digital display, the RCC-02 provides clear and comprehensive indications on the state of the system in the chosen language.

The device memorizes the events that occurred on an installation and therefore anticipates any future problems.

 

Date Time & Special Function

Date Time & Special Function

A SD card reader is available and allows parameters recording, as well as the uploading of various pre-settings and of all future updates.

Meant for wall mounting.
Dimension H x L x l: 170 x 168 x 43.5 mm.
Supplied with 2 m cable (max. 50m)

You can also download the manual through the link below.
Studer RCC-02 and RCC-03 User Manual

Buy this product through any of the following:

  • Telephone Order – Call 0803 2170 129
  • PRAG Showrooms (Lagos, Port Harcourt or Abuja) Click Here
  • Order from KONGA Click Here
  • Order from JUMIA Click Here

Price Options

xxx

Specifications

Inverter 
ModelXTH 6000-48
Nominal battery voltage48 Vdc
Input voltage range38 – 68 Vdc
Continuous power @ 25°C5000 VA
Power 30 min. @ 25°C6000 VA
Power 5 sec. @ 25°C15 kVA
Maximum loadUp to short-circuit
Asymmetric loadUp to Pcont.
Load detection (stand-by)2 to 25 W
Cos j0.1-1
Maximum efficiency96 %
Consumption OFF/Stand-by/ON1.8 W / 2.2 W / 22 W
Output voltagePure sine wave 230 Vac (± 2 %) / 120 Vac (1)
Output frequencyAdjustable 45 – 60 Hz (1) ± 0.05 % (crystal controlled)
Harmonic distortion< 2 %
Overload and short-circuit protectionAutomatic disconnection with 3 time restart attempt
Overheat protectionWarning before shut-off – with automatic restart
Battery charger
Charge Characteristic6 steps: Bulk, Absorption, Floating, Equalization, reduced floating, periodic absorption
Number of steps, thresholds, end current and times completely adjustable with the RCC-02/-03
Maximum charging current100 A
Temperature compensationWith BTS-01 or BSP 500/1200
Power Factor Correction (PFC)EN 61000-3-2
General dataXTH 6000-48
Input voltage range150 to 265 Vac / 50 to 140 Vac (1)
Input frequency45 to 65 Hz
Input current max. (transfer relay) / Output current max.50 Aac / 56 Aac
Transfer time<15 ms
Multifunction contacts2 independent contacts (potential free 3 points, 16Aac / 5Adc)
Weight42 kg
Dimensions h/w/l [mm]230 / 300 / 500
Protection indexIP20
EU declaration of conformityLow Voltage Directive (LVD) 2014/35/EU:
– EN 50178:1997
Electromagnetic Compliance (EMC) Directive 2014/30/EU:
– EN 62040-2:2006, EN 61000-3-2:2014, EN 61000-3-12:2011
Operating temperature range-20 to 55°C
Relative humidity in operation95 % without condensation
VentilationForced from 55°C
Acoustic level< 40 dB / < 45 dB (without/with ventilation)
Warranty5 years
ISO Certification9001:2008 / 14001:2004
Accessories
Remote control RCC-02 or RCC-03Adjustable with the RCC-02/-03
Module Xcom-232iAdjustable with the RCC-02/-03
Communication sets Xcom-LAN / Xcom-GSM / Xcom-SMSAdjustable with the RCC-02/-03
Battery Status Processor BSPAdjustable with the RCC-02/-03
Remote Control Module RCM-10 (3 m)Adjustable with the RCC-02/-03
2 aux. contacts module ARM-02
Cooling Module ECF-01
Battery temp. sensor BTS-01 (3 m)Adjustable with the RCC-02/-03
Communication cable for 3ph and // CAB-RJ45-8-2Adjustable with the RCC-02/-03
Mounting frame X-Connect
Call Now Button